Ultraviolet Radiation Sensor
|
These photovoltaic detectors are optimized for UV(Ultra Violet) region based on III-V GaN (Gallium Nitride)
epitaxial material responding to light only in the UV range. These detectors are packaged in electrically
isolated TO-46 housing with an integrating filtered window and other packages are available on customer¡¯s
request. UV radiation exposure, known to be the cause of skin cancer and other skin damage, is of increasing
concern. However, using available detectors to date, accurate measurements of UV dosages under solar or sun
lamp exposure have been, at best, difficult to make.
Our ACUV-2002T detector has been specially developed to solve this problem. The spectral response of this
schottky type detector is corresponds closely to the erythemal response spectrum in solar.
|
¢Ã Features |
- Schottky type photodiode
- Spectral response according to CIE erythemal
response spectrum
- Integrated filter
- TO-46 metal package and low profile
- SMD type available
|
¢Ã Applications |
- Measurement of erythema effective UV,
part of Sun or UV lamp radiation
- UV dosimeter for skin care
|
|
|
¢Ã General Ratings / Absolute Maximum Ratings |
Window Material |
Package |
Effective Active Area (§±)
|
Absolute Maximum Ratings |
Reverse Voltage VR (V)
|
Operating Temperature TOPR(¡É)
|
Storage Temperature TSTG(¡É)
|
Filtered UV glass |
TO-46 |
0.29 |
5 |
-20~+80 |
-40~+85 |
¢Ã Electro-Optical Characteristics at 25¡É |
Spectral Response Range ¥ë (nm) |
Dark Current ID (nA)
|
Terminal Capacitance CT (pF)
|
280~370 |
£¼ 1.0 |
15 |
|
|